Temperature Controlled Environmental Triaxial Apparatus
ENVIRONMENTAL TRIAXIAL TESTING SYSTEM
This high-quality stress path high-pressure temperature-controlled triaxial test system is a fully automatic system that uses an active triaxial cell with a built-in axial loading mechanism (based on Bishop & Wesley cell type) that controls stress directly on the sample. In Addition to the active cell, the system includes three high-pressure volume pressure controllers (VPC), an internal submersible load cell to measure axial load, a pressure transducer to measure pore water pressure, a linear displacement transducer to measure vertical displacement, a lifting mechanism, and temperature controlling unit.
The triaxial cell is made from stainless steel and specifically designed for high-pressure tests under various temperature conditions and has an internal submersible load cell for axial load measurement. This system needs 3 Advanced volume pressure controllers for the axial load (lower chamber), cell pressure and one for back pressure.
- Features
- Specifications
- Software
- Standards
- Applications
- High Stiff system
- Easy sample setup and handling of the test
- Sample Size up to 50mm in diameter
- Different Cell pressures from 8MPa up to 30MPa
- Different Axial Loads from 7kN up to 150kN
- Cyclic Temperature tests from -20 °C up to 100°C
- Vertical lifting mechanism for triaxial cell
- Horizontal sliding mechanism for Triaxial cell
- Microprocessor-controlled precision
- Direct operation of the device by a PC with controlling software (communication protocol is available)
SAMPLE SIZE/S |
38mm - 50mm / 70mm-100 mm |
SAMPLE HEIGHT /DIAMETER RATIO |
2:1 |
CELL PRESSURE |
10 MPa / 20 MPa |
MAX. AXIAL LOAD |
25kN / 50kN / 100kN |
MAX. AXIAL LOAD WITH MOTORIZED VERSION |
50kN |
PRESSURE ACCURACY |
0.1% F.S |
VOLUME ACCURACY |
0.1% F.S |
RANGE OF TESTING TEMPERATURE |
From -20 °C to Ambient temperature From ambient temperatures to +200°C From -20°C to 200°C |
DIMENSIONS (MAIN DEVICE): WXDXH |
1039*1466*2389mm |
WEIGHT |
650Kg |
POWER SUPPLY |
230 V AC /50Hz |
- Data Acquisition, processing, and device management (DPD) Module
- Saturation Module
- B-value -Test Module
- Consolidation Module (Isotropic or anisotropic)
- Permeability Test Module
- Stress path module: Linear stress paths- p, q or s, t
- Static Shear Stage Module: UU: Unconsolidated Undrained Triaxial Test (Total Stress test)
- Static Shear Stage Module: CU: Consolidated Undrained Triaxial Test with pore pressure measurement (Effective Stress test)
- Static Shear Stage Module: CD: Consolidated Drained Triaxial Test with pore pressure measurement (Effective Stress test)
- Unsaturated Test Module
- K0 Test Module
- Not available
- Detailed information will follow soon